NSF/ANSI 42
Aesthetic effects: chlorine, chloramine, taste, odour, particulates.
NSF International and IAPMO R&T public listings
Six cartridges, five systems, one page. Choose a cartridge to see what it is certified for, what it has been tested for, what is still in testing, and what it does not claim. Every figure comes from an independent laboratory against the protocol named next to it.
Loading cartridge information…
A certification means an accredited body tested the product and lists it publicly. A lab test to the same protocol produces the same data without the listing. Each standard below shows which cartridges hold which.
Aesthetic effects: chlorine, chloramine, taste, odour, particulates.
NSF International and IAPMO R&T public listings
Lead content: no part touching the water contains more than 0.25% lead by weighted average.
NSF International public listing
Health effects: lead, mercury, PFOA/PFOS, VOCs, cysts, fluoride and other contaminants with a health limit.
IAPMO R&T
Emerging compounds: pharmaceuticals, hormones, flame retardants, pesticides, microplastics.
IAPMO R&T
Plastic materials in contact with food and water; declaration of compliance for the tap filter's seals and non-metal parts.
Independent accredited European laboratory
Harmonised certification of materials in contact with drinking water (Delegated Regulation 2024/370, Implementing Decision 2024/368), applicable from 31 December 2026.
DVGW CERT (notified body)
Water Supply (Water Fittings) Regulations: materials in contact with wholesome water.
Independent UK drinking-water compliance assessment
Loading contaminant results…
No contaminants match these filters.
Gravity cartridges use the standard 1/4-inch thread, so they interchange across every euroguard gravity system and most compatible gravity housings.
| System | Classic Carbon | TriPure™ | TriCera Flow™ | TriCera™ Fluoride | CeraCore™ | Under-counter |
|---|---|---|---|---|---|---|
| euroguard One gravity system Polished stainless-steel gravity system | ✓ | ✓ | ✓ | ✓ | — | — |
| Gravity filter — Midnight Black & Moonlight White (6 L / 8.5 L) Powder-coated stainless steel | ✓ | ✓ | ✓ | ✓ | — | — |
| 12 L family gravity system Large-capacity stainless-steel gravity system | ✓ | ✓ | ✓ | ✓ | — | — |
| Stainless steel tap filter 304 stainless steel housing, diverter, 4 adapters | — | — | — | — | ✓ | — |
| Under-counter system Durable housing with push-fit installation | — | — | — | — | — | ✓ |
A controlled process makes every number easier to understand, compare and trace back to a named protocol.
The laboratory adds a measured concentration of each target contaminant to controlled source water. Temperature, pH, pressure and flow are recorded so every test can be repeated under the same conditions.
Challenge water passes through a new cartridge in the housing it is designed for. Samples are taken at defined intervals, including near the rated capacity, to measure how performance changes through its service life.
Accredited analytical methods compare the water before and after filtration. Results are reported as concentrations, percentage reduction or log reduction, then checked against the requirements of the named test protocol.
Certified, independently lab-tested and in-progress results are labelled separately. Complete reports and supporting references can be requested from the euroguard team.
The activated carbon in every cartridge is certified by NSF International to NSF/ANSI 42 (chlorine, taste and odour) and NSF/ANSI/CAN 372 (lead content). Health-contaminant results to NSF/ANSI 53 and 401 come from testing to those protocols at IAPMO R&T, an ISO/IEC 17025 laboratory, and are shown as lab-tested rather than certified.
Because they are different filters. A carbon block handles chlorine, PFAS, lead and organics. A ceramic shell or UF membrane adds bacteria and cysts. Activated alumina adds fluoride. Anti-scale resin adds hardness. The table only shows a claim where the cartridge has the stage that makes it, so a carbon-only cartridge never lists bacteria as pending.
The ceramic and UF cartridges are tested against bacteria and cysts, and the TriCera™ Fluoride is designed for well and spring water. For well water with a high bacterial load, test the source first and use two cartridges. No cartridge on this page claims virus reduction unless the table says so.
A log reduction is a power of ten. Log 3 is 99.9%, log 4 is 99.99%, log 6 is 99.9999%: one organism in a million gets through. Laboratories report bacteria this way because the challenge water contains millions of organisms per litre.
Yes. Report numbers are listed on each cartridge's panel above, and we email the full documents on request.
Find your best filtration setup
Tell us about your tap, water source and priorities. We'll point you to the most suitable euroguard cartridge and system.
Testing was carried out under controlled laboratory conditions on new cartridges in euroguard housings. Contaminants were added to the challenge water at the concentrations shown and measured after filtration. Performance in your home depends on your water, the age of the cartridge and how the system is used. Not all contaminants listed will be present in your water. Gravity and tap cartridges without a ceramic or UF stage are intended for municipally treated water; ceramic and UF cartridges tested against bacteria and cysts may be used with water of unknown microbiological quality only as stated on the product page. Where no NSF/ANSI protocol exists for a contaminant, the laboratory's accredited method is stated in the report. Certification listings can be verified on the certifying body's public database. NSF/ANSI, IAPMO, DVGW, Eurofins, Berkey, Doulton and British Berkefeld are the marks of their respective owners; compatibility statements do not imply endorsement.